1. Design conditions

Exhaust gas parameters (provided by the customer):

Exhaust gas: Organization exhaust gas: 5--150Nm³/h,

Exhaust gas pressure: 0.02bar (g)

Exhaust gas temperature: 40

Exhaust gas humidity: saturated, aqueous aerosol content - Up to 50 g/m³

The composition can vary from 70%N2/30%CO2 to 10%O2/20%CO2/40%CH4/30%N2. Composition changes are always very smooth - it takes hours for each parameter to go from min to max;

Fuel: Natural gas P = 6-12 bar (requires regulator)

 

2. Public utilities conditions

Demineralized water

Pressure

0.3Mpa(G)

Temperature

Room temperature

Electrical

Electrical

380V, 50Hz, 3-phase five-wire

Meter

220V, 50Hz, single phase

Compressed air

Pressure

0.6Mpa(G)

Temperature

Room temperature

Instrument air

Pressure

0.6Mpa(G)

Temperature

Room temperature

Fuel

Fuel

Natural gas

Calorific value

8500Kcal/m³

Temperature

Ambient temperature

 