21009A H-500×2 Hydrogen Generator
Tag No.:21009A
Model:H-500×2
Name:Hydrogen Generator
1. General performance and utilities/consumables consumption
1 |
General performance |
|||||||||
|
Description |
Output |
Purity |
Pressure |
Temperature |
Dew Point |
||||
Gas hydrogen |
≥500Nm3/hr×2 |
≥99.999% H2 |
1.6MPa G |
30~40°C |
≤-60°C |
|||||
Gas oxygen |
≥250Nm3/hr×2 |
≥99.5% O2 |
1.6MPa G |
30~40°C |
≤-60°C |
|||||
Note: 1.1The output flow Nm3 is volume under normal conditions (0°C, 0.1013 MPa A). 1.2 The performance is based on design basis of clause 1 in this technical annex.1.3 The output flow of the hydrogen/oxygen is adjustable between 30~100% of total installed power. |
||||||||||
2 |
Electricity requirement |
|||||||||
|
SN |
Equipment |
Installed power/Shaft power, KW High Voltage |
Installed power/Shaft power, KW Middle Voltage/Low Voltage |
||||||
2.1 |
Rectifier cabinet (Water electrolyzer) |
3500×2/2300×2 |
|
|||||||
2.2 |
Lye pump |
|
15 |
|||||||
2.3 |
Feed water pump |
|
10 |
|||||||
2.4 |
De-oxygen tower |
|
40 |
|||||||
2.5 |
Hydrogen dryer heater |
|
100 |
|||||||
2.6 |
De-hydrogen tower |
|
20 |
|||||||
2.7 |
Oxygen dryer heater |
|
50 |
|||||||
2.8 |
Instrumentation control system |
|
5 |
|||||||
2.9 |
Demineralized water machine |
|
10×2 |
|||||||
2.10 |
Gas hydrogen compressor |
|
(45+3+1+1.1) ×4 |
|||||||
2.11 |
Gas oxygen compressor |
|
(45+3+1+1.1) ×2 |
|||||||
2.12 |
Water cooling system |
|
90 |
|||||||
2.13 |
Water chiller |
|
128.2 |
|||||||
2.14 |
Chilled water recycle pump |
|
15 |
|||||||
2.15 |
Instrumental air system |
|
6.5 |
|||||||
|
Total installed power |
~7800.3 |
||||||||
|
Tentative total consumption power (Based on shaft power) |
~5400.3 |
||||||||
|
Rated specific power consumption (DC) |
4.4+/-0.2 KWH/Nm3 H2 |
||||||||
|
Note: N2.1: Standard industrial power consumption tolerance: + 4% N2.2: Preliminary for reference only, and may adjust during detail design stage. |
|||||||||
3 |
Recycle cooling water requirement |
|||||||||
|
SN |
Equipment |
Recycle quantity T/hr |
|||||||
3.1 |
Gas liquid separator unit |
153 |
||||||||
3.2 |
Gas hydrogen compressor |
5×4 |
||||||||
3.3 |
Gas oxygen compressor |
5×2 |
||||||||
3.4 |
Water chiller |
67 |
||||||||
|
Total |
250 |
||||||||
4 |
Chilled water |
|||||||||
|
SN |
Equipment |
Recycle quantity T/hr |
|||||||
|
4.1 |
Rectifier cabinet (Water electrolyzer) |
|
|||||||
|
4.2 |
Hydrogen purification unit |
20 |
|||||||
|
4.3 |
Oxygen purification unit |
10 |
|||||||
|
|
Total |
30 |
|||||||
5 |
Instrument air |
|||||||||
|
Flow |
~25Nm3/hr |
||||||||
6 |
Gas nitrogen |
|||||||||
|
Quantity |
200Nm3 |
||||||||
7 |
Demineralized water |
|||||||||
|
Flow |
1000L/hr |
||||||||
8 |
Chemicals |
|||||||||
|
KOH (Potash Hydroxide) |
3500Kg |
||||||||
V2O5 |
20Kg |
|||||||||
9 |
Lubrication oil |
|||||||||
|
9.1 |
Gas hydrogen compressor |
50Kg×4 |
|||||||
9.2 |
Gas oxygen compressor |
50Kg×2 |
||||||||
10 |
Refrigerant |
|||||||||
|
10.1 |
Water chiller |
160kg |
|||||||
11 |
Refrigerant oil |
|||||||||
|
11.1 |
Water chiller |
16L |
For more details, please feel free to contact us by email to sales@wintekgroup.com
Key Words: Hydrogen Generator, Water Electrolysis Hydrogen Production Equipment, Hydrogen Production