11049A KDON-550/17000-60Y Gas Nitrogen/Liquid Nitrogen Cryogenic Air Separation Plant
Tag No.:11049A
Model:KDON-550/17000-60Y
Name:Gas Nitrogen/Liquid Nitrogen Cryogenic Air Separation Plant
General performance and utilities consumption:
1 |
General performance |
||||||||||
|
Description |
Output |
Purity |
Pressure out of cold box |
|||||||
|
|
|
|
||||||||
Gas oxygen |
550Nm³/hr |
99.9% O2 |
20MPa G |
||||||||
Gas nitrogen |
17000Nm³/hr |
≤ 5ppm O2 |
0.45MPa G |
||||||||
Liquid nitrogen (or replaced by liquid oxygen) |
60 Nm³/hr (or replaced by 55Nm³/hr liquid oxygen) |
≤ 5ppm O2 (99.9% O2) |
0.45MPa G (0.05MPa G for liquid oxygen) |
||||||||
Note: 1. Nm³ means volume under standard conditions (0 deg C, 0.1013 MPa.A) 2. The performance is based on design basis of item 1 in this technical annex. 3. Standard industrial performance tolerance: Output: + 2% Purity: 0% 4. This performance is under warranty. 5. The output flow shall be able to adjust 80~100%. 6. Both liquid oxygen and liquid nitrogen should have nozzles to connect to liquid tanks. |
|||||||||||
2 |
Electricity requirement |
||||||||||
|
SN |
Equipment |
High voltage KW |
Low voltage 1 KW |
Low voltage 2 KW |
||||||
1 |
Air filter |
|
1 |
|
|||||||
2 |
Main air compressor |
2000*2/1893.75*2 (by buyer confirmation) |
|
|
|||||||
3 |
Air pre-cooling system |
|
|
|
|||||||
|
Cooling water pump |
|
30*2 |
|
|||||||
|
Water chiller |
|
90 |
|
|||||||
4 |
Air purifier |
|
530(average ~180) |
|
|||||||
5 |
Turbine expander |
|
|
|
|||||||
|
Oil pump |
|
5*2 |
|
|||||||
|
Oil heater |
|
5 |
|
|||||||
6 |
Control system |
|
|
1 |
|||||||
|
|
|
|
|
|||||||
7 |
Liquid oxygen pump |
|
15*2 |
|
|||||||
8 |
Total installed power |
4677 |
|||||||||
9 |
Total shaft power |
4099.5(specific power consumption 4099.5KWH/17000Nm³=~0.241KWH/Nm³ gas nitrogen) The gas oxygen and liquid nitrogen are not calculated in the specific power consumption. |
|||||||||
10 |
Standard industrial power consumption tolerance: + 4% |
||||||||||
|
11 |
Instrumental air system power consumption |
|||||||||
|
12 |
Instrumental air compressor |
550/460 |
|
|
||||||
|
13 |
Instrumental air dryer |
80/74.25 |
|
|
||||||
3 |
Recycle cooling requirement |
||||||||||
|
SN |
Equipment |
Recycle quantity Ton/hr |
||||||||
1 |
Main air compressor |
280*2 |
|||||||||
2 |
Air pre-cooling system |
120 |
|||||||||
3 |
Turbine expander |
20 |
|||||||||
4 |
Instrumental air compressor |
50 |
|||||||||
5 |
Total |
750 |
|||||||||
4 |
Instrument air |
||||||||||
|
Flow |
~500Nm³/hr |
|||||||||
5 |
Operation period between 2 defrosting |
1 years |
|||||||||
6 |
Quality warranty period |
||||||||||
|
12 months from startup or 18 months from shipment, as per the earlier one |
||||||||||
7 |
Design service life for air separation plant |
20 years |
For more details, please feel free to contact us by email to sales@wintekgroup.com
Key Words: Air Separation Plant,Gas Separation Plant,Oxygen Generator