1.Technical parameter of the Unit
|
SN |
Name |
Parameter |
|
1.1 |
Model |
BGYL-4780F/17Y |
|
1.1 |
Natural gas processing capacity |
4780 Nm³/h |
|
1.3 |
Inlet temperature |
60℃ |
|
1.4 |
Natural gas inlet pressure |
1.7 MPa G |
|
1.5 |
Cooling method |
Air cooling |
|
1.6 |
Power |
400 V/50 HZ |
|
1.7 |
Work mode |
Continuous work |
|
1.8 |
Natural gas outlet temperature |
37℃ |
|
1.9 |
Rated cooling capacity |
315 KW |
|
1.10 |
Shaft power |
79 KW |
|
1.11 |
Rated power |
110 KW |
|
1.12 |
Operating current |
130 A |
|
1.13 |
Minimum distribution power |
110 KW |
|
1.14 |
Energy regulation |
25% -100% infinitely adjustable |
|
1.15 |
Diameter of natural gas connection pipe |
DN125 |
|
1.16 |
Pressure loss |
≤10 KPa |
|
1.17 |
Refrigerant |
R134A |
|
1.18 |
Cooling method |
Air cooling |
|
1.19 |
Structure |
Copper sleeve aluminum fin |
|
1.20 |
Ambient temperature |
≤42℃ |
|
1.21 |
Number of blowers |
10 sets |
|
1.22 |
Single blower air capacity |
15000 m3/h |
|
1.23 |
Single blower power |
1.1 KW |
|
1.24 |
Protection grade of motor |
ExhdⅡ BT4 |
|
1.25 |
Equipment installation location |
Indoor |
|
N1 |
Note |
|
|
N1.1 |
The cooling capacity refers to the cooling capacity of compressed natural gas under standard conditions of inlet and outlet, with an ambient temperature of ≤42℃. |
|
2. Main supply and configuration list
|
SN |
Name |
Unit |
Qty |
Brand |
|
2.1 |
Explosion proof compressor |
Set |
1 |
Hanzhong Exhd Ⅱ BT4 |
|
2.2 |
Air-cooled condenser |
Pc |
4 |
Hengxing or equivalent |
|
2.2 |
Condenser blower |
Set |
10 |
Ruibo or equivalent |
|
2.4 |
Oil separator |
Set |
1 |
Lengde or equivalent |
|
2.5 |
Outlet globe valve |
Pc |
1 |
AMG or equivalent |
|
2.6 |
Liquid storage tank |
Set |
1 |
Sifeite or equivalent |
|
2.7 |
Return valve |
Pc |
1 |
AMG or equivalent |
|
2.8 |
Outlet valve |
Pc |
2 |
Lüzhou or equivalent |
|
2.9 |
Dry filter |
Pc |
1 |
Xingfeng or equivalent |
|
2.10 |
Dry filter element |
Pc |
3 |
Aimosheng |
|
2.11 |
Evaporator |
Set |
1 |
Jinduo or Sanchuan |
|
2.12 |
Hydraulic solenoid valve |
Pc |
2 |
Shangheng or equivalent |
|
2.12 |
Expansion valve |
Pc |
2 |
Danfoss |
|
2.14 |
Cooling medium pressure gauge |
Pc |
2 |
Shangyi or equivalent |
|
2.15 |
Pressure sensor |
Pc |
2 |
Shangyi or equivalent |
|
2.16 |
Temperature sensor |
Pc |
2 |
Shangyi or equivalent |
|
2.17 |
Return oil filter |
Pc |
1 |
Fasike or equivalent |
|
2.18 |
Return oil solenoid valve |
Pc |
1 |
Shangheng or equivalent |
|
2.19 |
Oil sight glass |
Pc |
1 |
Danfoss |
|
2.20 |
Explosion proof solenoid valve coil |
Pc |
3 |
Baode or equivalent |
|
2.21 |
Ball valve with protective cover |
Pc |
3 |
Beiting or equivalent |
|
2.22 |
Safety valve |
Pc |
3 |
Beiting or equivalent |
|
2.23 |
Refrigerant |
Pc |
1 |
Juhua or equivalent |
|
2.24 |
PLC |
Pc |
1 |
Customization |
|
2.25 |
Explosion proof electrical box |
Pc |
1 |
Customization |
|
N2 |
Remark |
|||
|
N.2.1 |
Pre-cooling equipment inlet and outlet temperature, with remote transmission, compressor can be remotely stopped, with operation status indication. |
|||